| WT-HC |
Flows 50l/min - 125l/min
Pressures up to 420 bar
|
Webtec test units use pressure sensors & turbine flow meters to determine the parameters within a hydraulic system. They can measure & record for reference information in a variety of different formats. Typical applications are for trouble shooting hydraulic systems, when it is required to know exactly what pressures / flows & temperatures exist within the system.
|
 |
|
|
ADVANTAGES
ACCURATE MEASUREMENT OF PRESSURE & FLOW
HC units provide an accurate measurement of pressure, flow & temperature to an accuracy of + or - 2%.
PORTABLE & CONVENIENT
Units can can sustain reverse flow for unrestricted connection & simplified testing.
LOADING VALVE
Optional loading valves can be fitted to the turbine block to provide pressure loading mode.
BSP PIPE LINE MOUNTING
Units are supplied with 'in-line' 3/4" BSP ports for ease of mounting.
Ordering
WT-HC50FT-2547
WT-HC125FT-2525
|
Description
Hydraulic test unit for bidirectional flow 2 to 50 litres per minute and pressures up to 420 bar
Hydraulic test unit for bidirectional flow 4 to 125 litres per minute and pressures up to 400 bar |
Temperature
Oil temperature should be between +30ºC & +60ºC during normal operation. Oil life is greatly reduced if temperature exceeds 60ºC. As a general rule, oil life is halved for each 8ºC temperature exceeds 60ºC.
Filtering
It is necessary to keep the level of contamination within a hydraulic system at an acceptable level to ensure trouble free operation. Filtration should always be specified at a level that protects the most sensitive item or component in the system. |
|