| HP-2B |
Displacement 14 cc/cycle
Reservoir capacity 3.4 litres
Pressures up to 210 bar
|
Hand pumps comprise a piston assembly that displaces oil on every stroke by drawing from the oil reservoir & discharging via a non return valve assembly. Typical applications are for emergency operation of a system actuator in the event of power failure.
|
|
|
|

ADVANTAGES
GASKET SIDE MOUNTING
Units supplied with side face gasket mounting flange but no reservoir.
DOUBLE ACTING MANUAL OPERATION
HP pumps are supplied with 600mm double action handles.
INTEGRAL VALVES
Units are supplied complete with integral adjustable relief valve & manual release valve.
SIDE OR FOOT MOUNTINGS
Pumps can be side or foot mounted to suit.
Ordering
HP-2B
|
Description
Hand Pump 14cc per cycle, side gasket mounted c/w 660mm handle assembly and 3.4 litre reservoir
|
Temperature
Oil temperature within any system should ideally be between +30ºC & +60ºC during normal operation. Oil life is greatly reduced if temperature exceeds 60ºC. As a general rule oil life is halved for each 8ºC temperature exceeds 60ºC.
Filtering
It is necessary to keep the level of contamination within a hydraulic system at an acceptable level to ensure trouble free operation. Filtration should always be specified at a level that protects the most sensitive item or component in the system.
|
|