Ordering
D-CD1W
D-RM2-W
D-RM3-W
D-RQ5-W
D-RQM5-W |
Description
Relief valve 0-350 bar pipeline mount. Max flow 3 lpm, 1/4" NPT.
Relief valve 0-350 bar pipeline mount. Max flow 50 lpm, 3/8" BSP.
Relief valve 0-350 bar pipeline mount. Max flow 75 lpm, 1/2" BSP.
Relief valve 0-350 bar pipeline mount. Max flow 250 lpm 3/4" BSP.
Relief valve 0-350 bar with solenoid unloading, pipeline mount. Max flow 250 lpm, 3/4" BSP. |
Temperature
Oil temperature should be between +30ºC & +60ºC during normal operation. Oil life is greatly reduced if temperature exceeds 60ºC. As a general rule, oil life is halved for each 8ºC temperature exceeds 60ºC.
Filtering
It is necessary to keep the level of contamination within a hydraulic system at an acceptable level to ensure trouble free operation. Filtration should always be specified at a level that protects the most sensitive item or component in the system. |