Ordering
D-MERS
D-ERS4M
D-ERS07M |
Description
Flow restrictor to CETOP 3. 350 bar & 75 lpm. Define meter in or out. Define P, A or B port control.
Flow restrictor to CETOP 5. 320 bar & 100 lpm. Define meter in or out. Define P, A or B port control.
Flow restrictor to CETOP 7. 320 bar & 250 lpm. Define meter in or out. Define P, A or B port control. |
Temperature
Oil temperature should be between +30ºC & +60ºC during normal operation. Oil life is greatly reduced if temperature exceeds 60ºC. As a general rule, oil life is halved for each 8ºC temperature exceeds 60ºC.
Filtering